When moving, the RC servo motor velocity will be limited by this value.
RCServoMinVelocityLimit and RCServoMaxVelocityLimit.RCServoSpeedRampingState controls whether or not the velocity limit value is actually applied when trying to reach a target position.RCServoVelocityLimit to +RCServoVelocityLimit, depending on direction.RCServoTargetPosition, RCServoVelocityLimit, and RCServoAcceleration are configured by scaling the internal timing (set with RCServoMinPulseWidth and RCServoMaxPulseWidth) to a user specified range with RCServoMinPosition and RCServoMaxPosition.See RCServoTargetPosition for a deeper explanation of how the settings of your RC Servo controller interact to move your servo.

|
|
Device In Device # Identification |
|
|
error in (no error) error in can accept error information wired from VIs previously called. |
|
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
code code is the error or warning code. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
source source describes the origin of the error or warning. Right-click the error in control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
Velocity Limit The velocity value
1061_0 (ver: 100) RC Servo Motor Controller: Min: 0 Max: 6467.368357894737 Default: 180
1061_0 (ver: 200) RC Servo Motor Controller: Min: 0 Max: 6467.368357894737 Default: 180
1061_1 (ver: 300, 301, 302, 303, 304) RC Servo Motor Controller: Min: 0 Max: 6467.368357894737 Default: 180
1066_0 (ver: 100) RC Servo Motor Controller: Min: 0 Max: 6467.368357894737 Default: 180
1066_1 (ver: 100, 101) RC Servo Motor Controller: Min: 0 Max: 6467.368357894737 Default: 180
RCC0004_0 (ver: 400) RC Servo Motor Controller: Min: 0 Max: 6467.368357894737 Default: 180
RCC1000_0 (ver: 106) RC Servo Motor Controller: Min: 0 Max: 74013.15789473684 Default: 180
RCC1000_0 (ver: 110, 111, 120, 121) RC Servo Motor Controller: Min: 0 Max: 74013.15789473684 Default: 180
RCC1000_1 (ver: 200) RC Servo Motor Controller: Min: 0 Max: 74013.15789473684 Default: 180 |
|
|
Device Out Same as Device In |
|
|
error out error out passes error or warning information out of a VI to be used by other VIs. |
|
|
status status is TRUE (X) if an error occurred or FALSE (checkmark) to indicate a warning or that no error occurred. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
code code is the error or warning code. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |
|
|
source source describes the origin of the error or warning. Right-click the error out control on the front panel and select Explain Error or Explain Warning from the shortcut menu for more information about the error. |